
Input filter design and test strategy for dual unsynchronized Sine Amplitude Converters (SAC™) in space power systems
This paper presents a complete design methodology for input filters in redundant power-conversion systems
Weaving looms take spun cotton yarns and combine them into a woven fabric. Loom manufacturers are looking for ways of reducing the size and cost of their equipment while improving equipment flexibility, allowing end-users to make quick changes to the cloth’s weight, pattern and style. The key goals were:
Typically hold-up and smoothing of the rectified 3-phase AC input is provided by a large bulk capacitor. By following the rectifier with a wide input range DCM DC-DC converter, this hold-up capacitor was completely eliminated, saving both bulk and cost. Stepper motors require the DC supply to source large pulses of current. A DCM can support large capacitive loads at its output and this capacitor reduced the peak current demands on the converter, and thus its size and cost. The capacitor provided power averaging of the high current pulses to the motor with the converter recharging the capacitor continuously between stepper motor load pulses.
Energy consumption and running costs were reduced by the supply’s improved power factor and high efficiency (94%)
Power averaging allowed a smaller (33cm2), lower weight power supply that could easily be integrated into the motor assembly
The DCMs are easily paralleled to provide higher power to meet the demands of larger motor drives
The power source to the loom was a 3-phase 115V AC supply, which was rectified to provide 300V DC. By following the rectifier with a wide input range DCM DC-DC converter, the hold-up capacitor was completely eliminated. To analyze this power chain, go to Vicor Whiteboard online tool.
Isolated regulated
Input: 9 – 420V
Output: 3.3, 5, 12, 13.8, 15, 24, 28, 36, 48V
Power: Up to 1300W
Peak efficiency: 96%
As small as 24.8 x 22.8 x 7.21mm
Input filter design and test strategy for dual unsynchronized Sine Amplitude Converters (SAC™) in space power systems
This paper presents a complete design methodology for input filters in redundant power-conversion systems
Innovative reliable power solutions for critical applications
A collection of technical resources aimed at educating users on the benefits of using modular power in aerospace and defense applications
Powering AI processors – 48V vertical power delivery changes the game
AI models demand huge current, driving legacy multiphase designs past 50 phases—causing space, thermal, and control limits Vicor addresses
Innovative 48V AI power architecture delivers both high current density and high current gain
Vicor 48V Factorized Power Architecture slashes thermal losses and delivers high current density to meet the extreme power demands of AI processors




